Dakota Ultrasonics MMX-7 v2.0 Thickness Gauge
Multimode thickness gauge for reading through paint and other material coatings.
Overview
Features
- 0.025in to 100ft range for pit and flaw detection
- 0.1 to 6.0in range for through paint and coatings
- 0.0122 to 0.7300in/µs velocity range
- 0.001in resolution
- Audible and visual alarm
- USB-C 1.1 PC & OSX output
- Rugged sealed aluminum case
- 2-year limited warranty
- Factory calibration NIST & MIL-STD-45662A
What's in the Box
- Thickness transducer (P/N T-102-2700)
- Couplant
- AA batteries
- Manual
- Carrying case
- Certificate of calibration
Description
The Dakota Ultrasonics MMX-7 v2.0 thickness gauge has all the features of the ZX gauges with some additional advantages. The MMX-7 features Pulse-Echo mode for pit and flaw detection and Echo-Echo mode for through paint and coatings, and users can conveniently toggle between the two modes.
The MMX-7 uses a highly damped, dual-element-style transducer for both modes, eliminating the need to switch between transducer types. The gauge is equipped with a transducer list for improved linearity, multiple calibration and selectable material type options. Transducers with an HD (high damped) designation are commonly used for E-E (echo-echo) through paint modes, CPZT (composite) are used for additional output with materials that are difficult to pass sound through, and standard diameter/frequency transducers are used for P-E (pulse-echo) mode.
The gauge offers selectable display options including large digits and B-Scan, a feature that displays a cross section of the test material and provides the user with a graphical view of the opposite or blind surface. The MMX-7 also features Windows PC and OSX interface software, and USB-C 1.1 connectivity. The gauge can store up to 64 custom, user-definable setups that can be transferred to and from a PC or Mac. The MMX-7 is packaged in an all-aluminum sealed case, making it rugged and resistant to the working environment.
Dakota MMX-7 Thickness Gauge Applications
- Corrosion and pitting
- Tube and pipe
- Tanks
- Boilers
- Glass
Documents
Accessories
Required Transducers
At least one transducer is required for this product
Accessories
Please consider these optional accessories.
Need Help? Call a Flow engineer at 1-800-884-4967
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET