Fluke 80i-110s AC/DC Current Clamp
10 or 100A current, 600V maximum voltage, with zero error adjustment and BNC connector.
Overview
Features
- 10 or 100A AC/DC nominal current range
- Continuous current range
- 0.1 to 10A AC/DC (100mV/A output)
- 1 to 100A AC/DC (10mV/A output)
- ±3% of reading +50mA (100mV/A, 50mA to 10A)
- ±4% of reading +50mA (10mV/A, 50mA to 40A)
- ±12% of reading +50mA (40 to 80A)
- ±15% of reading (80 to 100A)
- Maximum non-destructive current of 140A (2kHz)
- Lowest measurable current of 0.1A
- 100kHz useable frequency
- CAT II 600V & CAT III 300V
- 1-year warranty
This product is an accessory for the following products:
Description
The Fluke 80i-110s is compatible with any Fluke ScopeMeter test tool, power harmonics analyzer, oscilloscope, multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.
Documents
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET