Fisher R222H First-Stage Regulator
Up to 2,000,000 BTU/hr, POL or NPT inlets up to 250 psi and reduces to 4 to 12 psi, for two-stage residential LP-gas systems.
- By Fisher
Overview
Features
- 250 psig (17.2 bar) maximum inlet pressure
- Propane flow capacities up to 2,000,000 BTU/hr
- 1/2 or 3/4in female NPT or female POL inlet
- 1/2 or 3/4in female NPT outlet
- 3/8in NPT screened vent
- -20 to 160°F (-29 to 71°C) operating temperature
- 20-year recommended replacement life
- UL listed & CRN certified
Description
The Fisher R222H first-stage regulator is designed to reduce the tank pressure for the second-stage regulator in domestic applications. Inlet and outlet gauge taps allow for easy system testing, even in underground tanks. The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunction with an R622 or R652, the two-stage system will limit the downstream pressure from the second-stage to 2 psig even in a double failure situation.
Fisher equipment must be installed, operated and maintained in accordance with Federal, state, and local codes and Fisher instructions. Only personnel trained in the proper procedures, codes, standards and regulations of the LP-gas industry should install and service this equipment.
Need Help? Call a Flow engineer at 1-800-884-4967
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET