Honeywell OELD Optima Excel Local Display
Bluetooth-enabled local display for Searchpoint Optima Plus and Searchline Excel, non-intrusive interaction.
Overview
Features
- Bluetooth (BLE) range up to 10m (30ft)
- Materials:
- Marine-grade aluminium alloy
- 316 stainless steel
- Cable entries:
- 5 x M25 (ATEX/IECEx version)
- 5 x 3/4" NPT (cULus version)
- Non-intrusive interaction
- Ingress protection IP66 / Type 4X
- Multi-color backlight
- Operating temperature ranges:
- -40 to 149°F
- -76 to 149°F (CU TR-EX version only)
- 0 to 99% RH (non-condensing)
This product is an accessory for the following products:
Description
The Honeywell OELD Optima Excel Local Display is a smart junction box for the Searchpoint Optima Plus and Searchline Excel infrared detectors for flammable hydrocarbons. The OELD includes an LCD screen for gas information, a "traffic light" indicator for at-a-glance detector status, and Bluetooth connectivity for simplified, non-intrusive maintenance. Simply pair the OELD with our intrinsically safe, ruggedized smartphone; then use the OELD smartphone app to interact with the gas detector from up to 10 meters (30 feet) away. For maximum flexibility, the gas detector can be mounted either directly or remotely to OELD to suit any situation.
Documents
Spec Sheets
Manuals
- Honeywell OELD Optima Excel Local Display Manual PDF (2.2 MB)
- Honeywell OELD Optima Excel Local Display - App Manual PDF (1.2 MB)
Other
- Honeywell OELD Optima Excel Local Display Quick Spec Sheet PDF (195 KB)
- Honeywell Bump Test and Calibration Frequency Guidelines PDF (70 KB)
- Honeywell OELD Optima Excel Local Display - EU Declaration of Conformance (357 KB)
Links
Accessories
Applications
Here's how some of our customers use this product...
Ethanol Detection in a Distillery
The Background: Our customer is a small distillery that seeks a reliable and cost-effective means of detecting ethanol leaks.
The Problem: Ethanol is highly flammable making leaks potentially dangerous.
The Solution: We recommended the Honeywell OELD Optima Excel Local Display with a Honeywell Searchpoint Optima Plus ethylene sensor. This combo gives local indication of Ethanol level as well as a color changing display indicating an alarm condition. The customer may further automate the gas detection as they expand and this transmitter also includes a 4-20 mA output they can run to a centralized panel in the future.