Fluke i2000 Flex AC Current Clamp
20, 200, and 2000A current ranges with flexible head, voltage output, BNC connector, and banana adapter.
Overview
Features
- AC RMS current ranges with ±1% accuracy
- 20A (100mV/A output)
- 200A (10mV/A output)
- 2000A (1mV/A output)
- 10Hz to 20kHz frequency
- 100kΩ minimum load impedance
- 178mm maximum conductor diameter
- CAT III 600V safety rating
This product is an accessory for the following products:
Description
The Fluke i2000 Flex AC Current Clamp utilizes the Rogowski (air-cored coil) principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders, or data loggers. The flexible and light-weight measuring head allows quick and easy installation on thick and hard-to-reach areas.
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET