Measures liquid, gas or steam for pressures up to 1450 psia, universal HART communications protocol.
Measures liquid, gas, or steam for pressures up to 6,000 psi, universal HART communications protocol.
Measures liquid levels for pressures up to 426 psi, universal HART communications protocol.
Measures liquid, gas or steam for gauge pressures up to 7,252 psi, universal HART communications protocol.
Direct mount transmitter for absolute pressure measurements up to 435 psia, universal HART communications protocol.
Direct mount measurement for pressures up to 1,450 psi, and with universal HART communications protocol.
Measures liquid, gas or steam for pressures up to 1450 psia, universal HART or proprietary and faster Fuji communications protocol.
Measures liquid, gas or steam for pressures up to 6,000 psi, universal HART or proprietary and faster Fuji communications protocol.
Measures liquid levels for pressures up to 426 psi, universal HART or proprietary and faster Fuji communications protocol.
Measures liquid, gas or steam for gauge pressures up to 7,252 psi, universal HART or proprietary and faster Fuji communications protocol.
Direct mount transmitter for absolute pressure measurements up to 435 psia, universal HART or faster Fuji communications protocol.
Measures liquid, gas or steam for pressures up to 1450 psia, SIL 2/3 safety features, <80 ms response time, universal HART or proprietary and faster Fuji communications protocol.
Measures liquid, gas or steam for pressures up to 6,000 psi, SIL 2/3 safety features, <80 ms response time, universal HART or proprietary and faster Fuji communications protocol.
Measures liquid levels for pressures up to 426 psi, SIL 2/3 safety features, <80 ms response time, universal HART or proprietary and faster Fuji communications protocol.
Measures liquid, gas or steam for gauge pressures up to 7,252 psi, SIL 2/3 safety features, <80 ms response time, universal HART or proprietary and faster Fuji communications protocol.
Direct mount transmitter for absolute pressure measurements up to 435 psia, SIL 2/3 safety features, <80 ms response time, universal HART or faster Fuji communications protocol.
Direct mount measurement for pressures up to 1,450 psi, and with universal HART or proprietary and faster Fuji communications protocol.
Direct mount measurement for pressures up to 1,450 psi, SIL 2/3 safety features, <80 ms response time, with universal HART or proprietary and faster Fuji communications protocol.