Honeywell RAEGuard 2 PID
Fixed photoionization detector that measures a broad range of volatile organic compounds.
Overview
Features
- Digital Smart Sensor Technology
- Detection range options:
- 0.01 to 100ppm, 0.1 to 1000ppm, or 1 to 1000ppm
- Operates in flow-through mode
- Three wires, supports 4-20mA analog output
- RS-485 digital communication in ModBus protocol
- Explosion-proof stainless-steel enclosure
- For hazardous environment applications
- Adjust parameters without opening housing
- Matrix LCD of 128 x 64 supports graphic display
- LED alarms when High or Low alarm point is reached
- Operation at 10 to 28 VDC
- Three dry contacts
- (<30Vdc, 2A) normally open (or normally closed)
- High and Low alarm
- Fault alarm
What's in the Box
- Magnetic key
- Hex service tool
- Spare sensor lamp
- 10 pack of Teflon UV shields
- 5 pack of external water trap filters
- 5 pack of internal dust filters
- User manual
Description
The Honeywell RAEGuard 2 PID is a fixed photoionization detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog 4-20mA, three-wire signal output and RS-485 Modbus digital signal output.
The RAEGuard 2 PID uses an intelligent processing platform and digital sensor technology that supports multiple ranges and resolutions and is capable of environmental self-adaptation. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.
The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.
Some key applications for the RAEGuard 2 PID along with the PIDs involved include:
- Benzene in refinery analyzer shelters
- Ammonia in industry
- Vinyl Chloride in chemical manufacturing
- Toluene or Ammonia in semi-conductor plants
- Chlorine Dioxide, Hydrogen Peroxide, Ozone in pulp and paper
- Solvent and chemicals storage
- Phenol and DME in pharmaceutical
- Toluene in printing
- Air quality
- Methyl Ethyl Ketone in paint spray booths
- Heat transfer fluids
- Acetone, Xylene, Phenol in medical, pathology, histology lab
Documents
Spec Sheets
Manuals
Other
- Honeywell RAE Systems PID Instrument Response Guidelines (849 KB)
- Honeywell RAEGuard 2 PID Installation and Maintenance Guide (180 KB)
- Honeywell Bump Test and Calibration Frequency Guidelines (70 KB)
Application Notes and White Papers
Links
Accessories
Calibration
Sensors/Probes
Accessories
Please consider these optional accessories.
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET