Ametek ASC301 Signal Calibrator
Portable, robust custom housing, simultaneous read-back, fast RTD simulation.
Overview
Features
- Calibrate pressure or temperature
- Operating temperature: 14 to 122°F (-10 to 50°C)
- Simultaneous input and output
- High accuracy
- Temperature reading at reference level
- Fuseless protection
- Full numerical keypad
What's in the Box
- Set of test leads
- 4 AA Batteries
- Manual
- Soft case
- NIST traceable certificate
Description
The Ametek JOFRA ASC301 Signal Calibrator provides the functionality and accuracy you expect from a laboratory calibration system, but compact enough to fit into the tool box and be operated with one hand for easy field calibration.
The ASC301 is more than a signal calibrator. Combined with JOFRA's APM external pressure modules or a JOFRA dry-block calibrator, it will calibrate pressure and temperature, and used together with JOFRACAL even document it as well. For Workshop use a DC power supply is available.
The full numerical keypad with a series of function keys and the cursor keys, provide a simple and quick user interface. The new ClearBrite™ graphical display offer the best visibility.
The high accuracy of ASC301 has not been achieved on account of fragile measurements or source circuitry, the ASC301 has fuse less protection all the way up to 250 VAC – might save you a calibrator, lowers cost of ownership.
The ASC301 offers simultaneous input and output. This means that you can calibrate and adjust a temperature transmitter on the table with no other necessary instruments. Source the sensor signal loop and input the mA from the transmitter. If you select mA Loop the ASC301 will also supply the 24 VDC for the loop. In the display you will see both your output temperature and the return mA from the transmitter. Enter the zero and full scale values and you can make quick 10% or 25% steps or go direct to zero or full span values. The ASC301 has dedicated keys for this operation so adjustment on the transmitter is made easier.
The ASC301 offers the possibility to characterize an RTD sensor. Use this feature to add a missing special curve or to characterize a reference RTD. If you choose a reference RTD from the accurate and stable STS100 temperature sensors, they will be delivered with a traceable calibration certificate including the necessary Van Duesen coefficients. Enter the figures into the ASC301 and you have a temperature reference. Complement this with a JOFRA dry-block temperature calibrator and your ASC301 becomes the heart of your portable calibration lab.
If you by mistake connect the ASC301 to the mains supply, the instrument is protected with a fuseless protection feature. This feature protects the instrument on up to 250 VAC on any combination of connections made on the test lead connectors and prevents expensive repairs and recalibration of the instrument.