Overview

Features

  • SCFM, NM3/hr, Lbs/hr, Kg/hr and more
  • 100 to 1 turndown typical range
  • Measures process gas temperature
  • 4 to 20 mA for flow & temperature; pulse output for flow/total
  • RS232; RS422/RS485-Modbus, Profibus-DP, DeviceNet or Ethernet Modbus TCP
  • Insertion and in-line models
  • Welded 316 SS sensor
  • Hastelloy C276 sensor optional
  • Microprocessor based, field programmable electronics
  • On-board 2 line x 16 character, backlit display with configuration panel to view/set readings and parameters
  • Palm Handheld Terminal available to view/set readings and parameters
  • NIST traceable calibration
  • Low-end sensitivity for leak detection
  • Negligible pressure drop
  • No moving parts design
  • FM & FMc Class I, II, III, Div 2, Groups A, B, C, D, E, F, G T4A hazardous locations
  • NEMA 4X and CE approved
A completed FT2 application data form is required to purchase this meter. Please be prepared, we will contact you about your order.

Description

The Fox Thermal FT2 mass flow meter and temperature transmitter measures two important process variables in one rugged instrument. The Fox FT2 measures gas flow rate in standard units without the need for temperature or pressure compensation. It provides isolated 4 to 20 mA and pulse outputs for flow rate, and a 4 to 20 mA output for process gas temperature. The pulse output is normally used for totalization.

An optional on-board 2 line x 16 character, backlit display is available to view flow rate, total, elapsed time, process gas temperature, and alarms. The display is also used in conjunction with the Configuration Panel to configure flow meter settings, pulse output frequency scaling, pipe area, zero flow cutoff, flow filtering (damping), display configurations, diagnostics and high or low alarm limits.

The Fox FT2 is available in both insertion and in-line models. The insertion meter is easily installed by drilling a 3/4" hole in the pipe and welding on a 3/4" NPT coupling. A Fox supplied compression fitting secures the probe in place. The inline model is available in 1/4" to 6" sizes and includes built in flow conditioners that eliminate the need for long, straight pipe runs. The meter can be ordered with flange or NPT end connections.

Both models are supplied with 316 stainless steel wetted materials standard or Hastelloy C-276 as an option. RS232 for connecting a Palm Handheld or computer is standard. Interface options include RS422/RS485-Modbus, Profibus-DP, DeviceNet or Ethernet Modbus TCP.

Fox has certified cleaning and bagging procedures for flow meters to be used in oxygen applications.