AEMC PowerPad Jr. Model 8230 Power Quality Analyzer
Power quality analyzer for single-phase systems and three-phase balanced load networks.
Overview
Features
- Measures up to 660 V RMS or V DC
- Measures up to 6500 A AC or 1400 A DC (probe dependent)
- Displays min, max and averager volts and amps, crest factor, peak value and K-Factor
- Calculates and displays watts, VARs, kWh and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase
- Displays total harmonic distortion (THD-F and THD-R) for voltage and current
- Individual volt and amp hramonics are displayed in value and % to the 50th
- Captures, displays and stores inrush current waveforms and statistics
- Displays and records up to 17 different power quality parameters
- Determines phase rotation
- Stores up to eight screen captures
- Stores up to 1 MB of trend recorded data
- Captures up to 4096 alarm events using up to 10 different thresholds
- Configurable from DataView software or front panel
- Download stored data to DataView software via optical with isolated USB port
- Includes free DataView software for data storage, real-time waveform display, analysis and report generation
- Applications:
- Verification of power distribution circuits
- Measures and records power systems (kW, VA, kVAR)
- Energy metering (kAh, VARh, kWh)
- Determine harmonic content and its origins
- Motor analysis
Description
The AEMC PowerPad Jr. Model 8230 is a single-phase power quality analyzer that is easy-to-use, compact and shock-resistant. It is intended for technicians and engineers to measure and carry out diagnostic work and power quality work on single-phase systems and three-phase balanced load networks. Users are able to obtain instant waveforms of an electrical network's characteristics, and also monitor their variation over a period of time.
The multi-tasking measurement system of the 8230 simultaneously handles all the measurement functions and waveform display of the various parameters, detection, continuous recordings, and their display without any constraints.
The AEMC model 8230 ships complete with:
- Current probe w/10 ft lead
- Blk/Red 10 ft voltage leads and alligator clips
- Optical USB cable
- (1) NiMH battery
- 120 V US wall charger
- DataView software
- Carrying bag
- Manual
Electrical | |
---|---|
Voltage (TRMS) | MN-2 Probes: 240 A, 6 A/120 A; Phase-to-phase: 660 V; Phase-to-neutral: 600 V |
Current (TRMS) | MN Probe: 5 mA to 6 A/120 A or 2 to 240 A; MR Probe: 10 to 1000 A AC, 10 to 1400 A DC; SR Probe: 3 to 1200 A; AmpFlex: 10 to 6500 A |
Frequency (Hz) | 40 to 70 Hz |
Other measurements | kW, kVAR, PF, DPF, kWh, kVAh, K-Factor, Flicker, Harmonic Phase Shift, Phase Rotation, in RUSH |
Harmonics | THD-R, THD-F, V, A, VA, 1st to 50th, Direction, Sequence |
Sampling Frequency | 256 samples/cycle |
Inrush | Displays and records duration, 1/2 cycle max, peak and displays waveforms |
Data storage | 1.5 MB partitioned for waveforms, alarms and trendrecording |
Alarms | Stores up to 2096 events showing time, duration and value |
Power source | NiMH rechargeable battery pack; AC supply: 120/230 V AC (50/60 Hz) |
Battery life | ≥ Eight hrs with display on ≥40 hrs with display off (recording mode) |
Mechanical | |
Communication port | Optically isolated USB |
Display | 1/4 VGA (320 x 240) color LCD |
Dimensions | 8.3 x 4.3 x 2.4" (211 x 108 x 60 mm) |
Weight | 1.9 lbs (0.88 kg) |
Safety rating | EN 61010, 600 V CAT III, IP 54, Pollution Degree 2 |
Display | |
Display type | Color LCD |
Environmental | |
Operating temperature | 32 to 122° F (0 to 50°C) |
Storage temperature | (< 30 days) -4 to 122°F (-20 to 50°C) with batteries. |
Safety | |
Safety rating | EN 61010-31:2002, EN 61010-1; 2001, EN 61010-2: 1995, 600 V CAT III, Pollution Degree 2 |
Double insulation | Yes |
CE Mark | Yes |
Documents
Accessories
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open 8:00 am to 5:30 pm ET