The Testo 6351 differential pressure transmitter measures differential pressure, flow velocity and flow volume. The Testo 6351 has a measurement range of 50 Pa to 2000 hPa and automatic zero-point adjustment which guarantees high, temperature-independent accuracy and long-term stability.
The Testo 6351 differential pressure transmitter has many features including Ethernet, relay and analog outputs to allow optimum integration into existing automation systems. A display for easy adjustments via the operating menu and an optical alarm. The 6351 is compatible with P2A software which allows for the parameterization of unit and scale, sensor adjustment, analog output adjustment and adjustment history which can all be transferred to a PC for data storage and analysis. The self-monitoring transmitters guarantee high system availability.
Differential Pressure Parameters | ||
---|---|---|
Measuring Range | 0 to 50 Pa 0 to 100 Pa 0 to 500 Pa 0 to 10 hPa 0 to 50 hPa 0 to 100 hPa 0 to 500 hPa 0 to 1000 hPa 0 to 2000 hPa |
-50 to 50 Pa -100 to 100 Pa -500 to 500 Pa -10 to 10 hPa -50 to 50 hPa -100 to 100 hPa -500 to 500 hPa -1000 to 1000 hPa -2000 to 2000 hPa |
Measurement Uncertainty | ±0.8% of measurement range final value ±0.3 Pa | |
Selectable Units | Pa,more available | |
Sensor | Piezoresistive sensor | |
Automatic Zero-point adjustment | Via magnetic valve. Frequency settable: 15 sec, 30 sec, 1 min, 5 min, 10 min |
|
Overload | Measuring Range:0 to 50 Pa 0 to 100 Pa 0 to 500 Pa 0 to 10 hPa 0 to 50 hPa 0 to 100 hPa 0 to 500 hPa 0 to 1000 hPa 0 to 2000 hPa -50 to 50 Pa -100 to 100 Pa -500 to 500 Pa -10 to 10 hPa -50 to 50 hPa -100 to 100 hPa -500 to 500 hPa -1000 to 1000 hPa |
Overload: 20000 Pa 20000 Pa 20000 Pa 20000 Pa 200 hPa 750 hPa 750 hPa 2500 hPa 2500 hPa 20000 Pa 20000 Pa 20000 Pa 20000 Pa 200 hPa 750 hPa 750 hPa 2500 hPa 2500 hPa |
Analog Outputs | ||
Qunatity | 1 | |
Output type | 0/4 to 20 mA (4-wire) (24 VAC/DC) 0 to 1/5 to 10 V (4-wire)(24 VAC/DC) |
|
Measuring Cycle | 1/sec | |
Resolution | 12 bit | |
Scaling | Differential pressure: scalable ±50 % of measuring range final value; freely scalable within measuring range | |
Load | max. 500 Ω | |
Other Outputs | ||
Ethernet | Optional with Ethernet module | |
Relay | Optional: 4 relays (free allocation to measurement channels or as collective alarm in operating menu/P2A software), up to 250 VAC/3A (NO or NC) | |
Digital output | Mini-DIN for P2A software | |
Supply | ||
Voltage Supply | 20 to 30 VAC/DC, 300 mA current consumption, galvanically separate signal and supply line |
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET