DC Voltage |
|
400.0 mV 4.000, 40.00, 400.0 V 600 V |
±(.03% +4 dgt) ±(0.5% + 3 dgt) ±(1.0% + 4 dgt) |
|
NMRR: CMRR: |
>50 dB@DC, 50/60 Hz >120 dB@DC, 50/60 Hz, Rs=1 kHz |
|
Input Impedance: |
10 MΩ, 30 pF nominal(1000 MΩfor 400.0 mV range) |
|
Transient protection: |
6.5 kV (1.2/50 µs surge) |
AC Voltage (50 Hz ~ 500 Hz) |
|
4.000, 40.00, 400.0 V 600 V |
±(1.5% + 5 dgt) ±(2.0% + 5 dgt) |
|
CMRR: |
>60 dB @ DC to 60 Hz, Rs=1 kΩ |
|
Maximum crest factor: |
less than 1.75:1 at full scale & less than 3.5:1 at half scale |
|
Input impedance: Transient protection: ACD-10 TRMS-PLUS: |
10 MΩ, 30 pF nominal 6.5 kV (1.2/50 µs surge)
True RMS sensing - 5% to 100% of range |
AC Current (Clamp-on 50 Hz/60 Hz) |
|
40.00, 400.0, 600 A |
±(1.5% + 8 dgt)1,2,3 |
|
Overload proctections: ACD-10 TRMS-PLUS |
ACA Clamp-on jaws:600 A rms continuous
Average sensing
|
|
ACD-10 TRMS-PLUS |
True RMS sensing - 10% to 100% of range |
1) Max induced error from adjacent current carrying conductore:
0.05 A 2) Specified accuracy is from 1% to 100% of range and for measurements made at the jaw
center. When the conductor is not positioned at the jaw center, position errors introduced are: Add
2% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaw opening).
3) Add 8 digits to specified accuracy @ reading < 10% of range. |
Resistance |
|
400.0 Ω 4.000, 40.00, 400.0 kΩ 4.000 MΩ 40.00 MΩ
Open circuit voltage: Transient protection:
|
±(0.8% + 8 dgt) ±(0.6% + 4 dgt) ±(1.0% + 4 dgt) ±(2.0% + 4 dgt)
0.4 VDC typical 6.5 kV (1.2/50 µs surge) |
Frequency |
400.0 mVac 4.000 Vac 4.000, 40.00 Vac 400.0 Vac 600 Vac
400.0 Aac |
0 Hz ~ 2 kHz 5 Hz ~ 5 kHz 5 Hz ~ 100 kHz 5 Hz ~ 10 kHz 5 Hz ~ 5 kHz
40 Hz ~ 400 Hz |
±(0.5% + 4 dgt) ±(0.5% + 4 dgt) ±(0.5% + 4 dgt) ±(0.5% + 4 dgt)
±(0.5% + 4 dgt) ±(0.5% + 4 dgt) |
Display counts: |
5000 |
Resolution: |
0.001 Hz |
Overload protection: |
ACA Clamp-on jaws: AC 600 A rms continuous |
Transient protection: |
VAC input jacks: 6.5 kV (1.2/50 µs surge) |
Capacitance |
|
Range1 |
Accuracy2,3 |
|
500.0 nF, 5.000 µF 50.00 µF, 500.0 µF, 3000 µF |
±(3.5% + 6 dgt) |
1) Additional 50.00 nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8 V (approx. half full battery.)
Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4 V |
Transient protection: |
6.5 kV (1.2/50 µs surge) |
Audible continuity tester |
Audible indication: |
between 10 Ω and 120 Ω |
Transient protection: |
6.5 kV (1.2/50 µs surge) |
Max hold* (where applicable) Specified accuracy ± 50
digits for changes > 25 ms in duration |