$133.99
  • ACD-10 PLUS
  • Usually ships in 1-2 weeks

Overview

Features

  • AC & DC voltage to 600 V
  • AC current to 600 A
  • Thin jaws, only 10 mm (0.4" thick)
  • Resistance to 40 MΩ
  • Continuity buzzer
  • Capacitance to 3000 uF
  • Frequency measurement
  • In rush current
  • Hold & maximum reading functions
  • Accommodates conductors up to 26 mm (1.02") in dia.
  • Auto ranging

Description

The Amprobe ACD-10 PLUS is a 600 A clamp meter. Featuring jaws thinner than standard clamp meters, this Amprobe clamp meter is able to access tight measurement areas while still accommodating conductors up to 25 mm. The ACD-10 PLUS provides a full range of measurements and is a very versatile clamp-style multimeter.

The Amprobe ACD-10 PLUS clamp meter accurately measures AC & DC voltage to 600V, AC current to 600A, resistance to 40MΩ, capacitance to 3000 µF, and frequency. Frequency is measured by either jaws or test leads. Measurement values are easily viewed on the ACD-10 PLUS's 3-3/4 digit LCD display. Other features of the Amprobe ACD-10 PLUS include auto ranging, a continuity buzzer, relative zero mode, hold and maximum reading functions.

The Amprobe ACD-10 PLUS clamp multimeter ships complete with:

  • Test leads
  • Battery
  • Carrying pouch
  • Manual

Amprobe ACD-10 PLUS Clamp Multimeter Specifications

Feature Range Accuracy
DC Voltage
400.0 mV
4.000, 40.00, 400.0 V
600 V
NMRR:
CMRR:
Input Impedance
Transient protection:
±(0.03% + 4 dgt)
±(0.5% + 3 dgt)
±(1.0% + 4 dgt)
>50 dB@DC, 50/60 Hz
>120 dB@DC, 50/60 Hz, Rs=1 kHz
10 MΩ, 30 pF nominal (1000 MΩ for 400.0 mV range)
6.5 kV (1.2/50 µs surge)
AC Voltage (50 Hz ~ 500 Hz)
4.000, 40.00, 400.0 V
600 V
CMRR:
Maximum crest factor:
Input impedance:
Transient protection:
ACD-10 PLUS:
±(1.5% + 5 dgt)
±(2.0% + 5 dgt)
>60 dB @ DC to 60 Hz, Rs=1 kΩ
less than 1.75:1 at full scale & less than 3.5:1 at half scale
10 MΩ, 30 pF nominal
6.5 kV (1.2/50 µs surge)
Average sensing
AC Current
40.00, 400.0, 600 A
Overload proctections:
ACD-10 PLUS
±(1.5% + 8 dgt)1,2,3
ACA Clamp-on jaws:600 A rms continuous
Average sensing
1) Max induced error from adjacent current carrying conductor: 0.05 A
2) Specified accuracy is from 1% to 100% of range and for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 2% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaw opening).
3) Add 8 digits to specified accuracy @ reading < 10% of range.
Resistance
400.0 Ω
4.000, 40.00, 400.0 kΩ
4.000 MΩ
40.00 MΩ
Open circuit voltage:
Transient protection:
±(0.8% + 8 dgt)
±(0.6% + 4 dgt)
±(1.0% + 4 dgt)
±(2.0% + 4 dgt)
0.4 VDC typical
6.5 kV (1.2/50 µs surge)
Frequency
400.0 mVac
4.000 Vac
4.000, 40.00 Vac
400.0 Vac
600 Vac
400.0 Aac
0 Hz ~ 2 kHz
5 Hz ~ 5 kHz
5 Hz ~ 100 kHz
5 Hz ~ 10 kHz
5 Hz ~ 5 kHz
40 Hz ~ 400 Hz
±(0.5% + 4 dgt)
±(0.5% + 4 dgt)
±(0.5% + 4 dgt)
±(0.5% + 4 dgt)
±(0.5% + 4 dgt)
±(0.5% + 4 dgt)
Display counts: 5000
Resolution: 0.001 Hz
Overload protection: ACA Clamp-on jaws: AC 600 A rms continuous
Transient protection: VAC input jacks: 6.5 kV (1.2/50 µs surge)
Capacitance
  Range1 Accuracy2,3
  500.0 nF, 5.000 µF
50.00 µF, 500.0 µF, 3000 µF
±(3.5% + 6 dgt)
1) Additional 50.00 nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8 V (approx. half full battery.)
Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4 V
Transient protection: 6.5 kV (1.2/50 µs surge)
Audible continuity tester
Audible indication: between 10 Ω and 120 Ω
Transient protection: 6.5 kV (1.2/50 µs surge)
Max hold* (where applicable)
Specified accuracy ± 50 digits for changes > 25 ms in duration