Amprobe PM53A Digital Multimeter
Compact digital multimeter measuring AC & DC voltage, capacitance, resistance and frequency with AutoTect and VolTect technologies.
Overview
Features
- Display: 3-5/6 digit, 6000 count
- AutoTect - automatically detects AC or DC volts or resistance measurement
- VolTect - built-in noncontact voltage detector
- Max Voltage (AC or DC): 450 V
- Resistance: 6.000 MΩ
Description
The Amprobe PM53A digital multimeter is a shirt-pocket sized meter, just 3/8" thick and weighing less than 3 ounces. Despite its small size, the PM53A offers full functionality with AC and DC voltage to 450 V, resistance to 6 MΩ, capacitance to 100 µF, frequency to 30 kHz and continuity with beeper. The Amprobe PM53A also offers VolTect, a built-in, non-contact voltage detection for AC voltages.
A key feature of the Amprobe PM53A digital multimeter is AutoTect, which automatically selects AC voltage, DC voltage or resistance measurement based on the test point to which the leads are connected. Fully autoranging, this meter offers seven different measurement functions plus features that are usually found in much more expensive and larger meters.
The digital display is oversized with large digits and unit icons in the display. The PM53A is fully safety rated to CAT III 300 V, CAT II 450 V and is UL approved.
Amprobe PM53A digital multimeters ship complete with:
- Silicone protective holster
- Attached test leads
- Battery
- Manual
Amprobe PM53A Digital Multimeter Specifications
Function | Range | Accuracy | |
---|---|---|---|
DC Voltage | |||
6.000 V | ±(1.0% + 5 dgt) | ||
450.0 V | ±(1.2% rdg + 5 dgt) | ||
NMRR | > 30 dB @ 50 Hz/60 Hz | ||
CMRR | > 100 dB @ dc, 50 Hz/60 Hz;Rs=1 kΩ | ||
Input Impedance | AutoTect Lo-Z V DC: 160 kΩ, 160 pF nominal | ||
V DC AutoTect threshold | +1.2 V DC or < -0.6 V DC nominal | ||
AC Voltage | |||
50 Hz - 60 Hz | 6.000 V, 60.00 V, 450.0 V | ±(1.5% rdg + 5 dgt) | |
CMRR | > 60 dB @ dc to 60 Hz, Rs=1 kΩ | ||
Input Impedance | AutoTect Lo-Z V DC: 160 kW, 160 pF nominal | ||
ACV AutoTect threshold | +1.5 V AC 50 Hz/60 Hz nominal | ||
Capacitance | |||
500.0 nF, 5.000 µF, 50.00 µF | |||
100.0 nF, 1000 nF, 10.0 µF, | |||
100.0 µF 1 3 | ±(3.5% + 6 dgt)4 | ||
1Accuracy below 50 nF is not specified | |||
2Accuracies with film capacitor or better | |||
3Top range. Updates > 1 minute on large values | |||
4Specified with battery voltage above 2.8 V (half full battery). | |||
Resistance | |||
6.000 kΩ1 | ±(1.2% rdg + 6 dgt)2 | ||
60.00 KΩ, 600.0 KΩ | ±(1.0% rdg + 4 dgt) | ||
6.000 MΩ | ±(2.0% rdg + 4 dgt) | ||
Open circuit voltage | 0.4 V DC typical | ||
1AutoTect is for 6.000 kΩ ~ 6.000 MΩ ranges | |||
2Add 40 dgt to specified accuracy while reading is below 20% of range | |||
Frequency | |||
100 Hz, 1 kHz, 10 kHz1 | ±(0.5% + 4 dgt)< 20 V sine RMS | ||
1Sensitivity (Sine-rms): Hz in Auto-VW position:> 3 V | |||
VolTect | |||
Typical voltage | Bar graph indication | ||
15 V to 55 V | - | ||
30 V to 85 V | -- | ||
55 V to 145 V | --- | ||
85 V to 190 V | ---- | ||
above 120 V | ---- | ||
Indication | Bar graph segments & audible beep tones proportional to field strength | ||
Detection frequency | 50/60 Hz | ||
Detection antenna | Top left corner of the meter | ||
Audible continuity tester | |||
Open circuit voltage | 0.4 V DC typical | ||
Audible threshold | 175 Ω | ± 125 Ω |
Documents
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open 8:00 am to 5:30 pm ET