DC Volts
|
|
400 mV, 4 V, 40 V, 400 V, 600 V |
± (1.0% rdg + 2 dgts) |
Resolution |
0.1 mV |
|
Input impedance |
400 mV: greater than 100 mΩ; 4 V:10 MΩ; 40 V to 600 V: 9.1 MΩ |
|
Overload protection |
600 VDC or AC rms |
|
AC Volts
|
|
400 mV, 4 V, 40 V, 400 V, 600 V |
|
|
400 mV (50 to 100 Hz) |
± (2.0% rdg + 5 dgts) |
|
4, 40, 400, 600 V (50 to 100 Hz) |
± (2.0% rdg + 5 dgts) |
Resolution |
0.1 mV |
|
Input impedance |
400 mV: greater than 100 mΩ; 4 V:10 MΩ; 40 V to 600 V: 9.1 MΩ |
|
Overload protection |
600 VDC or AC rms |
|
DC Current
|
|
400 µA, 4000 µA, 40 mA, 400 mA, 10 A |
|
|
400 µA to 400 mA ranges |
± (2.0% rdg + 2 dgts) |
|
10 A range |
± (3.0% rdg + 3 dgts) |
10 A input: 10 A for 60 sec. max. followed by a 10 min. cooling period
|
Resolution |
0.1 µA |
|
Voltage burden |
0.2 V on 400 uA, 40 mA ranges |
|
|
2V on 4000 uA, 400 mA ranges |
|
Input protection |
0.5 A/500 V fast blow ceramic fuse (FP520) |
|
|
10 A/500 V fast blow ceramic fuse (FP540) |
|
AC Current
|
|
400 µA, 4000 µA, 40 mA, 400 mA, 10 A |
|
|
400 µA to 400 mA ranges |
± (2.5% rdg + 5 dgts) |
|
10 A range |
± (3.5% rdg + 5 dgts) |
10 A input: 10 A for 60 sec. max. followed by a 10 min. cooling period
|
Voltage burden: |
see DC Current |
|
Input protection: |
see DC Current |
|
Resistance
|
|
400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ |
|
Resolution |
0.1 Ω on 400 Ω range |
|
|
400 Ω to 400 kΩ ranges |
± (1.5% rdg + 4 dgts) |
|
4 MΩ range |
± (2.5% rdg + 4 dgts) |
|
40 MΩ range |
± (5.0% rdg + 5 dgts) |
Open circuit volts: |
-0.45 VDC (-1.2 VDC on 400 Ω range) |
|
Overload protection: |
600 VDC or AC RMS |
|
Frequency (Hz) (Auto ranging)
|
|
4 kHz, 40 kHz, 400 kHz |
|
Resolution |
1Hz |
± (0.1% rdg + 3 dgts) |
Sensitivity |
10 Hz ~ 400 kHz: > 3.5 V RMS |
|
Minimum pulse width: |
>2.5 us |
|
Duty cycle limits: |
>30% and >70% |
|
Overload protection: |
600 VDC or AC RMS |
|
Temperature
|
Ranges: |
-20°C to 1000°C (-4°F to 1832°F) |
|
Resolution |
0.1°C, 0.1°F |
|
|
-20°C to 10°C |
± (2.0% rdg + 4°C) |
|
10°C to 200°C |
± (1.0% rdg + 3°C) |
|
-20°C to 10°C |
± (2.0% rdg + 4°C) |
|
200°C to 1000°C |
± (3.0% rdg + 2°C) |
|
-4°F to 50°F |
± (2.0% rdg + 8°F) |
|
50°F to 400°F |
± (1.0% rdg + 6°F) |
|
400°F to 1832°F |
± (3.0% rdg + 4°F) |
Sensor type: |
K-type thermocouple |
|
Overload protection: |
600 VDC or AC RMS |
|
RPM
|
Range: RPM |
600 to 4000 RPM |
|
X10 RPM |
4000 to 12000 RPM |
|
Resolution: |
1 RPM |
± (2% rdg + 4 dgts) |
Effect Reading: |
1 RPM |
± (2% rdg + 4 dgts) |
Overload protection: |
600 VDC or AC RMS |
|
% Duty Cycle
|
|
1.0% to 90.0% |
|
Resolution: |
0.1% |
|
Pulse width: |
> 100 us, < 100 ms |
± (2% rdg + 5 dgts) |
Overload protection: |
600 VDC or AC RMS |
|
Dwell Angle
|
No. of cylinders: 4,5,6,8 |
|
|
|
4 CYL |
0 to 90.0° |
|
5 CYL |
0 to 72.0° |
|
6 CYL |
0 to 60.0° |
|
8 CYL |
0 to 45.0° |
Resolution: |
0.1° |
± (2% rdg + 5 dgts) |
Overload protection: |
600 VDC or AC RMS |
|
Continuity
|
Audible indication: |
Less than 25 Ω |
|
Response time: |
500 ms |
0 to 90.0° |
Overload protection: |
600 VDC or AC RMS |
|
Diode test
|
Test current: |
1.0 mA (approximate) |
± (3% rdg + 3 dgts) |
Resolution: |
10 mV |
|
Audible indication: |
< 0.25 V |
|
Open circuit volts: |
3.0 VDC typical |
0 to 90.0° |
Overload protection: |
600 VDC or AC RMS |
|