Amprobe 37XR-A Digital Multimeter
True RMS digital multimeter with component and logic test .
Overview
Features
- True RMS
- DC Voltage to 1000 V
- AC Voltage to 750 V
- DC and AC Current to 10 A
- Resistance to 40 MΩ
- Capacitance, Inductance, Frequency, Duty Cycle, dBm
- Continuity: Audible Indication < 40 W
- Diode Test
- Logic Test: TTL, CMOS
- Overload protection
- 4-3/4 digit; 10,000 count LCD
- 41-segment analog bar graph
- CAT III 600 V, CAT II 1000 V safety rating
- UL listed
Description
The Amprobe 37XR-A digital multimeter is a true RMS digital multimeter with a component and a logic test for troubleshooting electronic instrumentation in the lab or on the jobsite. The Amprobe 37XR-A can measure inductance to 40 Hz, frequency to 40 MHz, capacitance to 400 µF and logic to 20 MHz. The meter has a 10,000 count display with 0.1% accuracy at selected ranges.
Amprobe 37XR-A digital multimeters have many great features including an input warning tone when test leads are put in the wrong jacks; continuity beeper; Min/Max, Average, Relative, Peak and Data Hold; Auto power-off and a separate door for battery and fuse access. The Amprobe 37XR-A has a CAT III 600 V, CAT II 1000 V safety rating and is UL listed.
The Amprobe 37XR-A digital multimeter ships complete with:
- Test leads with threaded alligator clips (TL36A)
- 9 V battery
- Magne-Grip holster w/magnetic hanging strap (H2-XRA)
- Spare fuse
- Manual
Amprobe 37XR-A Digital Multimeter Specifications
Function | Range | Accuracy |
---|---|---|
DC Voltage | ||
Ranges | 1000 mV, 10 V, 100 V, 1000 V | ±(0.1 % rg + 5 dgt) |
Resolution | 100 µV | |
AC Voltage (45 Hz to 2 kHz) True RMS | ||
Ranges | 1000 mV, 10 V, 100 V, 750 V | |
750 V range: 45 to 1 kHz: | ±(2.0 % rdg + 10 dgts) | |
All other ranges: 45 to 500 Hz: | ±(1.2 % rdg + 10 dgts) | |
All other ranges: 500 to 2 kHz: | ±(2.0 % rdg + 10 dgts) | |
Resolution | 100 µV | |
AC coupled True RMS specified from 5 % to 100 % of range | ||
DC Current | ||
Ranges | 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A | |
100 µA range: | ±(0.5 % rdg + 10 dgts) | |
1000 uA to 400 mA ranges: | ±(0.5 % rdg + 5 dgts) | |
10 A range: | ±(1.5 % rdg + 10 dgts) | |
Resolution | 100 µV | |
AC Current (45 Hz to 1 kHz) True RMS | ||
Ranges | 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A | |
100 µA to 100 mA ranges: | ±(1.5 % rdg + 10 dgts) | |
400 mA range: | ±(2.0 % rdg + 10 dgts) | |
10 A range: | ±(1.5 % rdg + 10 dgts) | |
Resolution | 0.01 µA | |
AC coupled True RMS specified from 5 % to 100 % of range | ||
Resistance | ||
Ranges | 1000 Ω, 10 kΩ, 100 kΩ, 1000 kΩ, 10 MΩ, 40 MΩ | |
1000 Ω to 1000 kΩ ranges: | ±(0.5 % rdg + 8 dgts) | |
10 MΩ range: | ±(1.0 % rdg + 10 dgts) | |
40 MΩ range: | ±(2.0 % rdg + 10 dgts) | |
Capacitance | ||
Ranges | 40 nF, 400 nF, 4 µF 40 µF, 400 µF | |
40 nF, 400 µF ranges: | ±(3.0 % rdg + 10 dgts) | |
400 nF, 40 µF ranges: | ±(3.0 % rdg + 5 dgts) | |
Resolution | 0.01 nF | |
Inductance | ||
Ranges | 4 mH, 40 mH, 400 mH, 4 H, 40 H | |
For values of Q 2 7: | ±(5.0 % rdg + 30 dgts) | |
Resolution | 1 µH | |
Frequency | ||
Ranges | 100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz | ±(0.1 % rdg + 5 dgts) |
Resolution | 0.01 Ha | |
Duty Cycle | ||
Ranges | 0 to 90 % | |
Accuracy | 5V logic: | ±(2.0 % rdg + 20 dgts) |
Resolution | 0.01 % | |
Frequency Range | 0 % to 10 %: 40 Hz to 990 kHz | |
10 % to 90 %: 40 Hz to 20 kHz | ||
Logic Test | ||
Logic Type | TTL, CMOS | |
Thresholds | Logic 1 (Hi): TTL 2.8 V ±0.8 V, CMOS 4 V ±1 V | Logic 0 (Lo): TTL 0.8 V ±0.5 V, CMOS 2 V ±0.5 V |
Frequency Response | 20 MHz | |
dBm | ||
Ranges | -13 dBm to +50 dBm | |
45 Hz to 5 kHz: | ±(0.7 dB + 8 dgts) | |
5 kHz to 10 kHz | ±(2.5 dB + 8 dgts) | |
Resolution | 0.01 dBm | |
Continuity | ||
Audible Indication | less than 40 Ω | |
Diode Test | ||
Test Current | 1.0 mA (approximate) | |
Open Circuit Volts | 3.0 V dc typical | |
Peak | ||
AC Volts Accuracy | 100 V, 750 V ranges: | ± (3.0 % + 200 dgts) |
1000 mV, 10 V ranges: | unspecified | |
Overload Protection | ||
AC/DC Voltage | All ranges: 1000 V DC or 750 V AC RMS | |
AC/DC Current | µA/mA input: F0.5A/1000 V fast-blow ceramic (6.2 x 32 mm) | |
10 A for 4 min. max. followed by 12 min. cooling period |
Documents
Accessories
Test Leads
Cases
Need Help? Call a Temperature engineer at 1-800-884-4967