Isotech Drago 4934 Temperature Calibrator
Isocal-6 portable liquid bath calibrator for temperatures from 30 to 250°C, can be converted to a dry block calibrator.
Overview
Features
- 65 x 160mm calibration volume
- 8 x 8mm + 2 x 4.5mm, undrilled or custom drilled inserts
- ±0.03°C stability (Basic & Site models)
- ±0.005°C stability (Advanced model)
- Common uniformity specifications
- <0.007°C Radial, Liquid Bath mode
- <0.013°C Axial, Liquid Bath mode (40mm)
- <0.008°C Radial, Dry Block mode (between wells)
- <0.040°C Axial, Dry Block mode (40mm)
- 40min heating time from 30 to 250°C
- 90min to cool
- Meets ISO9000 requirements
What's in the Box
- Magnetic stirrer
- Probe basket
- 3 point traceable certificate
- Lid
Description
The Isotech Drago 4934 temperature calibrator provides an adjustable isothermal enclosure for calibration purposes. It is part of the award winning Isocal-6 family and with a reference probe can be used with different accessories for Dry Block, Infrared, Surface Calibration and even with ITS-90 Fixed Point Cells for uncertainties to 0.001°C. In Dry Block Mode, the large 65mm diameter block allows for the calibration of either larger probes or for calibrating many sensors simultaneously.
Basic Model
- Digital display of set and nominal block temperature
- Use with a separate external indicator to compensate for gradients and loading
- Calibrator does not need calibrating; only the indicator & sensor need re-calibration
- Cal Notepad software
- Serial PC interface
Site Model
- Digital display of set and nominal block temperature
- Single channel indicator for reference probe
- Best Practice calibration with established traceability and uncertainty
- Re-calibration requires sending whole unit in
- Cal Notepad software
- Serial PC interface
Advanced Model
- Digital display of set and nominal block temperature
- Three channel indicator for reference probe and units under test
- Advanced features including automatic temperature cycling and logging
- Best Practice calibration with established traceability and uncertainty
- Re-calibration requires sending whole unit in
- I-Cal Easy LOG software & built-in web server
- Ethernet & USB host PC interface
Documents
Accessories
Calibration
Software
Cases
Accessories
Please consider these optional accessories.
Applications
This product can be used in the following applications:
Here's how some of our customers use this product...
Calibrating and Testing Odd-Sized Probes
The Background: Our customer is an industrial facility that uses a large number of thermocouples in their processes. They seek a means to calibrate all of these thermocouples.
The Problem: The customer has been having a third party calibrate the thermocouples. In looking for ways to lower expenses they’ve decided to do the calibrations themselves. The thermocouples are of many sizes, shapes and ranges making it difficult to find a dry block calibrator that can handle all of the customer’s calibration needs.
The Solution: We recommended the Isotech Drago 4934 site version. The Drago 4934 is a liquid bath temperature calibrator which can handle any size or shape sensor and can calibrate to an accuracy of 0.1°C. The liquid bath performed very well and the customer is happy with the results.
Need Help? Call a Calibration engineer at 1-800-884-4967